English Version is Trial!

کاربران فارسی زبان لطفا به بخش فارسی مراجعه نمایند.

سیویلیکا به زبان فارسی

Advanced Search

Title
Author
(Last name)
Abstract
Keywords

About CIVILICA®

CIVILICA® provides professional papers published in national and international conferences.

This site is registered for BoomSazeh Construction Technology Development Co.

 

Contact Us:

Tel: 021-88008044

Email: Info [at]  CIVILICA [dot] com

 

 
Home Page E-mail us to: Info @ CIVILICA . com Tel: +98-21-88008044

ISSN 1735-5540   

 

Quick Search in Title, Abstract, and Keywords of Papers

Showing Abstract of Technical, economical and environmental evaluation of a solar absorption cooling system in Kerman

 
Links

[ Bug Reporting | Back | See this Article in Persian CIVILICA ]

Paper Details

[ Downloads: 5 | Abstract Viewed: 551 | Pages: 9 ]

Title

Technical, economical and environmental evaluation of a solar absorption cooling system in Kerman

Topic: Published Year: 1390
Presentation:
Published in:

[ 8th National Energy Congress ]

Original Language: English Full Text Size: Not Available

 

Abstract of the Article

 

Note: English CIVILICA is in its Trial Period so Full Texts can not be provided! Persian users can download it here

Download This article in PDF format Technical, economical and environmental evaluation of a solar absorption cooling system in Kerman

 

Authors:

[ Morteza Khalaji Assadi ] - Energy Engineering Department, Science and Research branch, Islamic Azad University, Tehran, Iran
[ Abtin Ataei ] - Energy Engineering Department, Science and Research branch, Islamic Azad University, Tehran, Iran
[ Amir Falahatkar ] - Energy Engineering Department, Science and Research branch, Islamic Azad University, Tehran, Iran

 

Abstract:

In recent years, Air conditioning appliances in buildings are responsible for a large percentage of the ozone depletion and greenhouse effect . The purpose of this research is to analysis of solar single effect lithium bromide-water absorption cooling system in a typical office building in Kerman. The solar energy is absorbed by heat pipe solar collectors and stored in an insulated storage tank. This system has been designed to supply the cooling load of mentioned typical office building where the cooling load is 35.17KW ( 10 tons of refrigerant) which events in July. Results demonstrate that depending on the Kerman climate and the specification of the building by means of optimized design of solar heat pipe collectors, up to 2500 m3/year Natural Gas energy saving can be reached by use of solar absorption cooling system. Achieving this purpose requires utilizing 13 collectors which everyone compromises 30 tubes with total absorber area of 41 m2 which is the optimum collector area for this plant in Kerman. According to this replacement the annual reduction of CO2 is equal or greater than 5 Kg and the investment payback rate would be 11.4 years which would be much shorter than the payback time of a solar cooling system combined with conventional all air systems.

 

Keywords:

Absorption cooling, Heat pipe collector, Solar energy

 

CIVILICA® - © BoomSazeh Construction Technology Development Co.

SAVAFA