Investigation on base-isolated structures in the regions of high seismicity
سال انتشار: 1390
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,194
فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
SEE06_171
تاریخ نمایه سازی: 16 اردیبهشت 1390
چکیده مقاله:
The base isolated buildings are considered high performance structures in seismic design approaches, therefore the proper prediction of their behaviors are noticeable in high seismic zones. In provisions, in seismic design of base-isolated structures several parameters affect the design base shear of superstructure; among them, spectral seismic coefficients ( ) which include the effect of constructions site conditions such as soil profile . seismic hazard level. distance to seismic source and seismic source type are notified. The focus of this paper is to investigate the dominant effect of high intensity of earthquake load caused by high seismic hazard level along with its source features. To achieve this aim, several nonlinear dynamic analysis were conducted to investigate the performance of a base-isolated building designed for a region of low seismicity, but subjected to a near-field characteristics. In this paper, a 2D steel frame building which sits on the LRB isolators is assumed to be located in near-fault regions, in order to take into account the effect of strong ground motion on the isolation system and superstructure.It was observed that storey drift and base shear force superstructures vulnerability index es and displacement of isolation system, isolation system vulnerability index were significantly increased. The basic vulnerable index which should be controlled primarily was displacement demand; afterward mitigating superstructure damage due to excessive story drift. It was concluded that the supplemental passive viscous energy absorbing devices such as viscous damper can be a good choice to limit displacement demand in isolation level to maximum design displacement but it can significantly increase the internal forces and also in some circumstances adding a supplemental viscous damper may lead to more drift in the superstructure.
کلیدواژه ها:
نویسندگان
r Cheraghi
Department of Civil Engineering, Imam Khomeini International University, Qazvin, Iran
r Izadifard
Department of Civil Engineering, Imam Khomeini International University, Qazvin, Iran,
m Ziyaeifar
Department of Civil Engineering, International Institute of Earthquake Engineering and Seismology Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :