Background and objective: Progressive loading protocol is a high-demanding procedure suggested to increase the quality of bone when the implant is inserted in D3 or D4-typed bone. The purpose of this study was to present a case report regarding simultaneously progressive and immediately loading implants in the anterior position of the maxilla.Patient Report: One patient whose implants in the anterior maxilla (in site of teeth #7, #9, #11) had questionable to poor prognosis who was treated immediate and delayed progressive loading protocol and was followed up for 2 years.Conclusion: Although the number of studies in this field is limited, it can be concluded that the progressive loading protocol can predictably enhance the treatment success in immediate-loaded implants with poor prognosis and when inserted in low quality bone such as the present case

نویسندگان

Safoura Ghodsi

Dental Research Center, Dentistry Research Institute, Department of Prosthodontics

Amirreza Hendi

Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran