چکیده مقاله:

Low-cost sensors based on Micro-Electro-Mechanical-Systems (MEMS) are typically used for attitude determination in navigation systems. Measured value of magnetometer is subjected to different kind of errors such as random noise, constant bias, nonorthogonality, scale factor deviation and more importantly hard iron and soft iron effects. Therefore, it is needed to calibrate these sensors for accurate measurement. One of the most common methods in calibrating magnetic sensors is least squares ellipsoid fitting. But, the common least squares ellipsoid fitting can be inefficient for real time applications. In this paper, a modified ellipsoid fitting method is proposed. In this method, nonlinear optimization is developed to minimize a novel cost function. The efficacy of the new algorithms is demonstrated through experimental results.

کلیدواژه ها:

magnetometer- calibration- ellipsoid fitting- nonlinear optimization

نویسندگان

Mojtaba Mirzaei

Assistant Professor, Hydro-Aeronautical Research Center, Shiraz University, Shiraz Iran

Iman Hosseini

Shiraz University, Shiraz, Iran PhD candidate, School of Electrical and Computer Engineering

Reza Babaei

Shiraz University, Shiraz, Iran PhD candidate, School of Mechanical Engineering