The impact of nanomaterials on signal amplification in a miRNA electrochemical sensor

سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 448

متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ELECTROCHEMISTRY011_303

تاریخ نمایه سازی: 5 بهمن 1395

چکیده مقاله:

Circulating miRNAs have been becoming as one of the most important biomarkers for cancer early detection (1). Biosensors are the attending class of miRNA quantification methods due totheir great specificity and selectivity. The electrochemical biosensors are the most attractive method, because of their inexpensive, fast and precise detection (2). Additionally, nanobiosensors are the biosensors which are using nanomaterials for signal amplifying andimproving the sensitivity of the detection system (3). Many of nanomaterials have been synthesized with different elements, shapes, structures, aspect-ratios and functionalization scheme, based on their goal application. In this research, graphene oxide and gold nanorodsapplied in an electrochemical nanobiosensor for miRNA quantification (4). The graphene oxide used for expanding the active area of electrode surface, and the gold nanorods attaching to the graphene oxide sheet to provide a media for attachment of thiolated single strand probes (SSprobe)(5-6). The probe was designed to specifically and selectively hybridize to the target miRNA. Additionally, Oracet blue used as an electroactive label which can intercalates withdouble strand oligonucleotide and the reduction signals of OB is measured by differential pulse voltammetry (DPV). The results showed that application of graphene oxide and gold nanorods are very effective in signal amplification and the current for nanobiosensor is much highercompared to the method that not used nanomaterials (Fig 1). In the optimization of experiments which is shown in the Fig 2, the maximum current for the nanobiosensor was achieved at the concentration of the graphene oxide and gold nanorods, 1.0 mg/mL and 100μg/mL, respectively. In conclusion, the application of nanomaterials, graphene oxide and gold nanorods, have extensively improved the electrochemical signals, succeeded the better sensitivity and lower detection limit

نویسندگان

Mostafa Azimzadeha

Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran,Tehran, Iran.

Mahdi Rahaie

Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran,Tehran, Iran.

Navid Nasirizadeh

Department of Textile and Polymer Engineering, Yazd Branch, Islamic Azad University, Yazd, Iran.

Hossein Naderi-Manesh

Department of Nanobiotechnology/Biophysics, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, Iran.

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • (2). Grieshaber, D., MacKenzie, R., Voros, J., Reimhult, E., 2008. ...
  • (4). Labib, M., Khan, N., Ghobadloo, S.M., Cheng, J., Pezacki, ...
  • (1). Ebert, M, S., Sharp, P, A., 2012. Cell. 27, ...
  • نمایش کامل مراجع