Comparing the Effect of Horizontal Canopy on Absorbing Radiation of Vertical Surfaces, (Case Study: Shrine of the prophet Khezr in Abadan and Shrine of Awn Ibn Ali in Tabriz)
محل انتشار: کنفرانس بین المللی علوم مهندسی، هنر و حقوق
سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 971
فایل این مقاله در 15 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ICESAL01_139
تاریخ نمایه سازی: 22 مهر 1394
چکیده مقاله:
This paper aims at measuring the performance of veranda in increasing utilization of solar energy in pilgrimage buildings of two different climates of Köppen zoning in Iran. Pilgrimage buildings were determined with the help of Analytic hierarchy process (AHP) of existing buildings with the chosen criteria of Likert of nine items. With the help of computationalmethod of Duffie, solar elevation angles and solar direction of Abadan (hot and humid) andTabriz (cold and dry) were extracted, and with the help of graphical methods , there was obtained hour shadow on first, tenth and twentieth of months of January and July. With thecomparison of the results, it was revealed that maximum solar elevation angle (the vertical radiation at 83) belongs to the first day of July, Abadan and the lowest (23.9) belongs to Tabriz on January twentieth inversely related with latitude. By comparing the percentage ofthe shadow area of wall behind veranda, we can say that in all samples the percentage of shadow was greater in summer than in winter, and in Tabriz with a cold climate, it became8.74 times. The entire building (100% area behind the veranda), the shrine of the prophetKhezr in Abadan is located in the shadow in the summer and annoying radiation does not hit it. In winter, in a city like Tabriz, only 5 percent of the daily facade is being stuck under theshadow showing the proper absorption of radiation in the cold climate. The results indicate integrating and applying the right direction and veranda in order to increase utilization of veranda in increased thermal comfort due to climatic absorption or the disposal of solar radiation.
کلیدواژه ها:
نویسندگان
Farah Habib
Professor, Pardis Branch, Islamic Azad University, Pardis, Iran.(Corresponding Author
Zahra Barzegar
Assistant Professor, Department of Art and Architecture, Payame Noor University (PNU), P.O.Box, ۱۹۳۹۵-۳۶۹۷, Tehran, Iran.
Maryam Cheshmehghasabani
Ph.D. Candidate, Department of Art and Architecture, Science and Research Branch, Islamic Azad University, Tehran, Iran.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :