Design and Evaluation of a Test Atmosphere System for Passive Samplers Development

سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 445

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_AOH-1-1_007

تاریخ نمایه سازی: 1 مرداد 1397

چکیده مقاله:

Background: Preparation of the test atmosphere is a crucial step in occupational health, toxicology, and analytical chemistry researches. Methods: A simple and efficient system was developed for preparation of standard test atmosphere for application in occupational and environmental exposure studies, especially passive sampler s validation. Results: The system applicability was tested in various temperature, humidity, and velocity conditions. Results showed that for testing the adsorbent samplers, the system should be in hybrid mode of dilution. Conclusion: The repeatability of the measurements in the proposed system was also examined that was in acceptable range. With double dilution system it is possible to produce concentrations less than part per million.

نویسندگان

Abdulrahman Bahrami

Department of Occupational Health, Research Centre for Health Sciences, Faculty of Public Health, Hamedan University of Medical Sciences, Hamadan, Iran