In-situ preconcentration, and electrochemical sensing of Zinc(II) and Copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology

سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 481

فایل این مقاله در 18 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_ICC-7-5_010

تاریخ نمایه سازی: 23 تیر 1398

چکیده مقاله:

A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane divided into pieces of 2 cm, then fiber s lumen and pores was satiated with homogeneous mixture of reduced graphene oxide (rGO) and three types used ionic liquids:(1-ethyl-3-methylimidazolium tetrafuoroborate), (1-butyl-3-methylimidazoliumhexafluorophosphate) and (1-butyl-2,3-dimethylimidazolium hexafluorophosphate) individually. Thereafter, a pencil graphite rod was placed inside the fiber. Fabricated sensors used for single-step simultaneous purification and determination of Zn(II) and Cu(II) ions from water samples. The response surface method (RSM) was used as the basis of the design and analysis of the experiments. Parameters that were most important in separation part of study such as: molar mass of ionic liquids, amount of nanoparticle and sonication time have been investigated. Analysis of variance (ANOVA) and RSM contour plots were presented for effect of all factors (input parameters) on the maximum current of differential pulse voltammetry (DPV) peaks (output responses). The results disclosed that the metal removal was impressed by the molar mass of ionic liquids, amount of nanoparticle and sonication time respectively. The efficiency specifications of this procedure were evaluated by calculating precision and response linearity. Under the optimal experimental conditions linear concentration ranges of 0.9–550µgL-1 and 0.7–500 µgL-1 were obtained for Zn(II) and Cu(II) ions respectively. The reported limit of detection for Zn(II) and Cu(II) were 0.27 and 0.21µgL-1 with relative standard deviations (RSD) 3.2%, and 4.4%, respectively. In addition, this sensor was successfully applied to real water samples.

کلیدواژه ها:

Zn(II) ، Cu(II) ، hollow fiber - pencil graphite electrode ، differential pulse voltammetry ، surface response method ، ionic liquid

نویسندگان

Ghobad Mansouri

Department of Chemistry, Payame Noor University, PO BOX ۱۹۳۹۵-۴۶۹۷ Tehran, Iran

Mohammd Bagher Gholivand

Faculty of Chemistry, Razi University, Kermanshah ۶۷۱۴۹۶۷۳۴, Iran

Zarrin Eshaghi

Department of Chemistry, Payame Noor University, PO BOX ۱۹۳۹۵-۴۶۹۷ Tehran, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Zh. Ren, W. Zhang, H. Meng, J. Liu, Sh. Wang, ...
  • C.G. Elinder, Handbook on the Toxicology of Metals, second ed., ...
  • J.O. Nriagu, Zinc in the Environment Part 1: Ecological Cycling. ...
  • B. L.O’Dell, History and status of zinc in nutrition. Fed. ...
  • T.G. Kazi, S.K. Wadhwa, H.I. Afridi, N. Kazi, G.A. Kandhro, ...
  • Z. Es’haghi, A. Nezhadali, H.A. Hosseini, S. Mohammadi-Nokhandani, Arabian Journal ...
  • G.Q. Mei, Harmfulness and treatment of heavy metal wastewater, Studies ...
  • A.G. Chmielewski, T.S. Urbanski, W. Migdal, Hydrometallurgy., 1997,45, 333–344. ...
  • R.W. Rousseau, Handbook of Separation Process Technology, Wiley, New York, ...
  • F. Valenzuela, C. Fonseca, C. Basualto, O. Correa, C. Tapia, ...
  • K. Mandel, F. Hutter, C. Gellermann, G. Sextl, Sep. Purif. ...
  • A. Raja, R. Subha, D. Jeyakumar, A.R. Burkanudeen, Sep. Purif. ...
  • H. Askun, B. Gulbakan, O. Celikbicak, C. Uzun, O. Guven, ...
  • F. Bai, Z. Fan, Microchim. Acta., 2007, 159, 235–240. ...
  • I. Narin, M. Soylak, Anal. Chim. Acta., 2003, 493, 205–212. ...
  • J. Komarek, R. Cervenka, T. Ruzicka, V. Kuban, J. Pharmaceut. ...
  • G. Yang, X. Qu, M. Shen, C. Wang, Q. Qu, ...
  • E. Espada-Bellido, M.D. Galindo-Riano, M. Garcia-Vargas, J. Hazard Mater., 2009, ...
  • C.R. Teixeira-Tarley, V. Silva- Santos, B.E.L. d- Baêta, A.C. Pereira, ...
  • F. Ricci, A. Amine, G. Palleschi, D. Moscone, Biosens. Bioelectron., ...
  • http://www.zimmerusa.com/electrodes.html. ...
  • M.D.F. Alpendurada, J. Chromatogr. A., 2000, 889, 3–14. ...
  • J. Pawliszyn, Solid phase microextraction: Theory and practice. New York: ...
  • G. Ouyang, J. Pawliszyn, Anal. Chim. Acta., 2008, 627, 184–197. ...
  • Z. Es haghi, T. Heidari, E. Mazloomi, Electrochim. Acta., 2014, ...
  • Z. Es haghia, M.A. Golsefidi, A. Saify, A.A. Tanha, Z. ...
  • Z. Es haghi, M. Ahmadi-Kalateh Khooni, T. Heidari, Spectrochim. Acta. ...
  • S. Pedersen-Bjergaard, K.E. Rasmussen, J. Chromatogr. A., 2008, 1184, 132–142. ...
  • F. Moeinpour, Z. Es’haghi, Iran. Chem, Commun., 2018, 6, 312-324. ...
  • Z. Es’haghi, F. Moeinpour Iran. J. Anal. Chem., 2014, 1, ...
  • P. Sun, D.W. Armstrong, Anal. Chim. Acta., 2010, 661, 1–16. ...
  • A. Abo-Hamad, M.A. AlSaadi, M. Hayyan, I. Juneidi, M.A. Hashim, ...
  • M. Hasanzadeh, N. Shadjou, M. Eskandani, M.D.L. Guardia, Trends Anal. ...
  • W.S. Hummers, R.E. Offeman, J. Am. Chem. Soc., 1958, 80, ...
  • P.W. Araujo, R.G. Brereton, Trends. Anal. Chem., 1996, 15, 156–163. ...
  • R. Brereton, Chemometrics: Data Analysis for the Laboratory and Chemical ...
  • M.A. Bezerra, R.E. Santelli, E.P .Oliveira, L.S. Villar, L.A. Escaleira, ...
  • G. Dingstad, B. Egelandsdal, T. Naes, Chemom. Intell. Lab. Syst., ...
  • K.M. Lee, D.F. Gilmore, Process. Biochem., 2005, 40, 229–246. ...
  • G. Derringer, R. Suich, J. Qual. Technol., 1980, 12, 214–219. ...
  • A. Muller, D. Flottmann, W. Schulz, Anal. Bioanal. Chem., 2008, ...
  • Z. Es’haghi, A. Nezhadali, H.A. Hosseini, S.M. Nokhandani, Arabian Journal ...
  • Z. Es’haghia, M. Khalili, A. Khazaeifara, G.H. Rounaghi, Electrochim. Acta., ...
  • P.R.D. Oliveira, A.C.L. Mendes, J.L. Gogola, A.S. Mangrich, L.H.M. Junior, ...
  • S. Chaiyo, E. Mehmeti, K. Zagar, W. Siangproh, O. Chailapakul, ...
  • Th.D.C. Oliveira, J.M. Freitas, R.A.A. Munoz, E.M. Richter, Talanta., 2016, ...
  • I.C. Santos, R.B.R. Mesquita, A.O.S.S. Rangel, Anal. Chim. Acta., 2015, ...
  • M. Tuzen, S. Sahiner, B. Hazer, Food. Chem., 2016, 210, ...
  • R. Galbeiro, S. Garcia, I. Gaubeur, J. Trace Elem. Med. ...
  • F. Shakerian, Sh. Dadfarnia, A.M. Haji Shabani, Food. Chem., 2012, ...
  • S. Yılmaz, S. Tokalıoglu, S. Sahan, A. Ulgen, A. Sahan, ...
  • نمایش کامل مراجع