چکیده مقاله:

Introduction: Microdosimeters are helpful for dose equivalent measurement in unknown radiation fields. The favorable physical and mechanical properties of the detector-grade chemical vapor deposition diamond materials have made the diamond microdosimeters suitable candidate for radioprotection applications in space. The purpose of this work is the investigation of the dose equivalent response of a typical diamond microdosimeter with laser-induced graphitized electrodes for use in space radiation fields. Materials and Methods: The Geant4 Monte Carlo simulation toolkit was applied to simulate the particle transport within the microdosimeter, and to determine the mean chord length and the dose equivalent response of the microdosimeter, based on the lineal energy dependent quality factor.   Results: The linear stopping power of the protons and alpha particles with energies higher than 5 MeV and 10 MeV respectively can be estimated within20% of deviation using the microdosimeter response. The fluence to dose equivalent conversion coefficients calculated affirms that there is an adequate agreement between the calculated coefficients and other research group results. Conclusion: The reasonable agreement between the dose equivalents calculated in this study and the results reported by other researchers confirmed that this type of microdosimeter could be a promising candidate suitable for the measurement of the dose equivalent in space radiation fields.

نویسندگان

firouz payervand

Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, Tehran, Iran

Gholamreza Raisali

Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, P.O.Box: ۱۱۳۶۵-۳۴۸۶, Tehran, Iran

fereshte Hajiesmaeilbaigi

Laser and Optics Research School, Nuclear Science and Technology Research Institute, AEOI, P.O.Box: ۱۱۳۶۵-۸۴۸۶, Tehran, Iran

shahyar Saramad

Energy Engineering and Physics Faculty, Amirkabir University of Technology, P.O.Box: ۱۵۸۷۵-۴۴۱۳, Tehran, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Verona C, Magrin G, Solevi P, Grilj V, Jakšić M, ...
  • The quality factor in radiation protection: report of a joint ...
  • Rossi BHH, Zaider M. Microdosimetry and its Applications: Springer; 1996. ...
  • Rossi HH, Rosenzweig W. A device for the measurement of ...
  • Davis JA, Guatelli S, Petasecca M, Lerch ML, Reinhard MI, ...
  • Bradley PD. The development of a novel silicon microdosimeter for ...
  • Dicello J, Amols H, Zaider M, Tripard G. A comparison ...
  • Buttar C, Conway J, Meyfarth R, Scarsbrook G, Sellin P, ...
  • De Angelis C, Bucciolini M, Casati M, Løvik I, Bruzzi ...
  • Davis JA, Ganesan K, Alves AD, Guatelli S, Petasecca M, ...
  • Rollet S, Angelone M, Magrin G, Marinelli M, Milani E, ...
  • Angelone M, Magrin G, Pillon M, Prestopino G, Rollet S, ...
  • Davis JA. Diamond microdosimetry for radioprotection applications in space: University ...
  • Davis JA, Ganesan K, Prokopovich DA, Petasecca M, Lerch ML, ...
  • Solevi P, Magrin G, Moro D, Mayer R. Monte Carlo ...
  • Burgemeister EA, inventor; U.S. Patent No. 4,511,783, assignee. Method for ...
  • Geis MW, Rothschild M, Ehrlich DJ, inventors; U.S. Patent No. ...
  • E. Alemanno AC, M. Catalano, G. Chiodini, G. Fiore, M. ...
  • De Feudis M, Caricato A, Martino M, Alemanno E, Ossi ...
  • De Feudis M, Caricato A, Taurino A, Ossi P, Castiglioni ...
  • Berger MJ, Coursey J, Zucker M, Chang J. Stopping-power and ...
  • Sato T, Endo A, Zankl M, Petoussi-Henss N, Yasuda H, ...
  • Stefan Roesler GRS. A FLUKA user-routine converting fluence into effective ...
  • Agostinelli S, Allison J, Amako Ka, Apostolakis J, Araujo H, ...
  • Allison J, Amako K, Apostolakis Jea, Araujo H, Dubois PA, ...
  • Guatelli S, Reinhard MI, Mascialino B, Prokopovich DA, Dzurak AS, ...
  • Anjomani Z, Hanu A, Prestwich W, Byun S. Monte Carlo ...
  • Jarlskog CZ, Paganetti H. Physics settings for using the Geant4 ...
  • Chauvie S, Guatelli S, Ivanchenko V, Longo F, Mantero A, ...
  • Santin G. Normalisation modelling sources.  Geant4Tutorial; Paris, France: 2007. ...
  • Dietze G, Bartlett D, Cool D, Cucinotta F, Jia X, ...
  • Spurný F. Space and Flights Radiation Protection. Czech Academy of ...
  • 0 Recommendations of the International Commission on Radiological Protection. ICRP ...
  • Prokopovich DA. Silicon on insulator microdosimetry for radiation protection in ...
  • Kellerer AM, Hahn K. Considerations on a revision of the ...
  • Agency IAE. Radiation Protection and Safety of Radiation Sources: International ...
  • Lin Z-W. Can the Equivalent Sphere Model Approximate Organ Doses ...
  • Clowdsley MS, Wilson JW, Kim M-H, Anderson BM, Nealy JE. ...
  • Borggräfe A, Quatmann M, Nölke D. Radiation protective structures on ...
  • Hu S, Kim M-HY, McClellan GE, Cucinotta FA. Modeling the ...
  • نمایش کامل مراجع