Optimized production and quality control of 68Ga-DOTATATE
محل انتشار: مجله پزشکی هسته ای ایران، دوره: 24، شماره: 1
سال انتشار: 1395
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 309
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJNM-24-1_004
تاریخ نمایه سازی: 21 بهمن 1398
چکیده مقاله:
Introduction: Optimized production and quality control of 68Ga-DOTATATE as an efficient and preferable PET radiotracer for somatostatin receptor imaging in neuroendocrine tumors is of great interest. In this study effort has been made to present a fast, efficient, cost-effective and facile protocol for 68Ga-DOTATATE productions for clinical trials. Methods:68Ga-DOTATATEwas prepared using generator-based [68Ga]GaCl3 and DOTATATE at optimized conditions for time, temperature, ligand amount, gallium content and column cartridge purification followed by proper formulation. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Results:68Ga-DOTATATE was prepared at optimized conditions in 7-10 min at 95°C followed by SPE using C18 cartridge (radiochemical purity 99±0.88% ITLC, > 99% HPLC, specific activity: 1200-1850 MBq/nM). The biodistribution of the tracer demonstrated high kidney uptake of the tracer in 10-20 min consistent with reported somatostatin receptor mappings. Conclusion: The entire production and quality control of 68Ga-DOTATATE is presented including labeling, purification, HPLC analysis, sterilization and LAL test) took 18-20 min with significant specific activity for administration to limited number of patients in a PET center.
کلیدواژه ها:
نویسندگان
Ayuob Aghanejad
Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
Amir Reza Jalilian
Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
Stephan Maus
Clinic of Nuclear Medicine, University Medical Centre Mainz, Langenbeckstrasse ۱, D-۵۵۱۳۱ Mainz, Germany
Hassan Yousefnia
Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :