Gallium‐68 DOTATATE Production with Automated PET Radiopharmaceutical Synthesis System: A Three Year Experience

سال انتشار: 1393
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 352

فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JNMB-2-2_001

تاریخ نمایه سازی: 12 تیر 1398

چکیده مقاله:

Objective(s): Gallium‐68 (Ga‐68) is an ideal research and hospital‐based PET radioisotope. Currently, the main form of Ga‐68 radiopharmaceutical that is being synthesised in‐house is Ga‐68 conjugated with DOTA based derivatives. The development of automated synthesis systems has increased the reliability, reproducibility and safety of radiopharmaceutical productions. Here we report on our three year, 500 syntheses experience with an automated system for Ga‐68 DOTATATE. Methods: The automated synthesis system we use is divided into three parts of a) servomotor modules, b) single use sterile synthesis cassettes and, c) a computerized system that runs the modules. An audit trail is produced by the system as a requirement for GMP production. The required reagents and chemicals are made in‐. The Germanium breakthrough is determined on a weekly basis. Production yields for each synthesis are calculated to monitor the performance and efficiency of the synthesis. The quality of the final product is assessed after each synthesis by ITLC‐SG and HPLC methods. Results: A total of 500 Ga‐68 DOTATATE syntheses (> 800 patient doses) were performed between March 2011 and February 2014. The average generator yield was 81.3±0.2% for 2011, 76.7±0.4% for 2012 and 75.0±0.3% for 2013. Ga‐68 DOTATATE yields for 2011, 2012, and 2013 were 81.8±0.4%, 82.2±0.4% and 87.9±0.4%, respectively. These exceed the manufacturer’s expected value of approximately 70%. Germanium breakthrough averaged 8.6×10‐6% of total activity which is well below the recommended level of 0.001%. The average ITLC‐measured radiochemical purity was above 98.5% and the average HPLC‐measured radiochemical purity was above 99.5%. Although there were some system failures during synthesis, there were only eight occasions where the patient scans needed to be rescheduled. Conclusion: In our experience the automated synthesis system performs reliably with a relatively low incident of failures. Our system had a consistent and reliable Ga‐68 DOTATATE output with high labelling efficiency and purity. There is minimal operator intervention and radiation exposure. The system is GMP‐compliant and has low maintenance and acceptable running costs. This system together with the recommended 68Ge/68Ga generator is well suited for use in a hospital‐based radiopharmacy

نویسندگان

Alireza Aslani

Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia

Graeme M Snowdon

Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia

Dale L Bailey

Faculty of Health Sciences, University of Sydney, Sydney, Australia

Geoffrey P Schembri

Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Wangler C, Wangler B, Lehner S, Elsner A, Todica A, ...
  • Ocak M, Antretter M, Knopp R, Kunkel F, Petrik M, ...
  • Petrik M, Knetsch PA, Knopp R, Imperato G, Ocak M, ...
  • cassette system. Nucl Med Commun. 2011;32(10):887‐95. ...
  • Decristoforo C, Knopp R, von GE, Rupprich M, Dreger T, ...
  • European Association of Nuclear Medicine. Gallium Edotreotide Injection Draft Monograph. ...
  • Petrik M, Knetsch PA, Knopp R, Imperato G, Ocak M, ...
  • نمایش کامل مراجع