Downstream Water Cooler, an Economical Choice over Destructive Burner: A Case Study of Shiraz Refinery

سال انتشار: 1392
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,948

فایل این مقاله در 9 صفحه با فرمت PDF و WORD قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

PROCESS01_007

تاریخ نمایه سازی: 11 خرداد 1392

چکیده مقاله:

In the coming pages the design of a water cooler is investigated in order to reduce the water carry-over from the waste gas stream of the Sour Water Treating plant. High water content prevents the gas to be burned inside the incinerator of the Sulfur Recovery unit and is unwillingly sent to the flare network resulting into corrosion issues and Slops formation. Upon simulating the whole water treating unit via Aspen v. 2006.5 to obtain operating data for the gas stream, using HTRI v. 5.0 a highly efficient water cooler is designed which practically condenses over 53 percent of water from the vapor phase making it suitable for introduction to the incinerator

کلیدواژه ها:

نویسندگان

Arash shamseddini

Department of Process Engineering, Shiraz Oil Refining Co.

majid yazdan panah

Head of Process Engineering Department, SORC

masoud oudbor

Senior Process Engineer