Impact of Dimensional Parameters and Depth of Penetration on Mutual Inductance and Electrical Resistance of ITCs Verify Analytical and Finite Element Methods

سال انتشار: 1389
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,591

فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

PSC25_008

تاریخ نمایه سازی: 24 بهمن 1390

چکیده مقاله:

A toroidal field coil (TFC) is composed of several individual toroidal coils (ITCs), which are connected in a series and distributed in a toroidal and symmetrical form. Cross section of ITCs is rectangular or negligible. This paper presents analytical equations of the mutual inductance of two ITCs applicable to Tokamak reactors using the filament method. These equations are based on those formulated by Neumann. The numerical analysis of the integrations resulting fro these equations is solved using the extended threepoint Gaussian algorithm. The finite element method (FEM) is employed to verify the mutual inductance equations of ITCs. The results obtained using the FEM, when dimensional parameters of ITCs are changed, confirms the analytical and empirical results showing an error of less than 0.2043% in the worst case. This indicates the reliability of the presented equations. This paper also employs FEM to obtain the depth of penetration of electromagnetic waves in high-conductivity conductors (HCCs). The results show that the ratio of the real depth of penetration, obtained by FEM, to the ideal depth of penetration in HCCs is independent of frequency. This ratio shows that the magnitude of traveling plane waves in HCC decreases with e−1.7916 rather than e−1.

کلیدواژه ها:

نویسندگان

M. R. Alizadeh Pahlavani

Department of Electrical Engineering, Iran University of Science and Technology (IUST), Tehran, Iran

A. Shoulaie

Department of Electrical Engineering, Iran University of Science and Technology (IUST), Tehran, Iran