CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

گواهی نمایه سازی مقاله Effects of PBTU30° & Rushton impeller combination on mixing time in stirred tanks

عنوان مقاله: Effects of PBTU30° & Rushton impeller combination on mixing time in stirred tanks
شناسه (COI) مقاله: ICHEC07_052
منتشر شده در هفتمین کنگره ملی مهندسی شیمی در سال ۱۳۹۰
مشخصات نویسندگان مقاله:

Amin Reza Ansari - Transport Phenomena Research Center,Chemical Engineering Department,Sahand University of Technology ,Tabriz,Iran)
Jafarsadegh Moghaddas - Corresponding Author Address: (Transport Phenomena Research Center,Chemical Engineering Department,Sahand University of Technology ,Tabriz,Iran)

خلاصه مقاله:
The aim of this study is to compare the different configuration of PBTU and Rushton impellers.All the experiments carried out in a stirred vessel with aspect ratio of 1.8 and D/T= 1/3.Investigation on mixing intensity variation is performed through measuring mixing time; which, its datas are obtained by Conductivity Probe technique. At the first, dual same Rushton and PBTU30° are enhanced to compare its mixing efficiency. However, like other literature, the radialimpeller type (PBTU30°) provide better mixing efficieny. Then, the hybrid impeller is applied. The position of impeller type in upper or lower of stirred tank, effects the mixing intensity whereas, combination of different impellers, greatly improved the homogenity. The bestconfiguration is PBTU30-RT that imply on locating Rushton turbin near the bottom of tank. Overally, this combination improve the mixing efficiency approximately 15 percent as comarison to RT-RT combination.

کلمات کلیدی:
Impeller, Mixing time, Rotational speed, stirred tank, axial, radial, pumping capacity,power number

صفحه اختصاصی مقاله و دریافت فایل کامل: https://www.civilica.com/Paper-ICHEC07-ICHEC07_052.html