CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Effectiveness of Bench Top Non-Vacuum Autoclaves on Dental Turbine Chamber Sterilization

عنوان مقاله: Effectiveness of Bench Top Non-Vacuum Autoclaves on Dental Turbine Chamber Sterilization
شناسه ملی مقاله: JR_JDMT-2-3_001
منتشر شده در شماره 3 دوره 2 فصل در سال 1392
مشخصات نویسندگان مقاله:

Taraneh Movahhed - Maxillofacial Diseases Research Center, Department of Community Oral Health, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
Behjatalmolook Ajami - Department of Community Oral Health and Department of Pediatric Dentistry, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
Mahboobe Dehghani - Dental Research Center, Department of Orthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
Ehsan Kiamanesh - Dental Research Center, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran

خلاصه مقاله:
Introduction: Dental turbine chamber is a suitable reservoir for living microorganisms, so chamber sterilization is necessary for reducing cross contamination risk. On the other hand, in non-vacuum autoclaves, steam penetration into turbine chamber is doubtful, while they are still in use in dental clinics. In this study, performance of small non-vacuum autoclave in turbine chamber sterilization was evaluated. Methods: A total of 48 dental turbines were sterilized by large vacuum autoclaves. The turbin chamber cap was opened in aseptic enviroment and a strip contaminated with bacillus stearothermophilus endospores was placed into chamber and chamber cap was closed. Twelve dental turbines were loaded in each of four autoclaves (2 large pre-vacuum autoclaves, 2 bench top non-vacuum autoclaves) and sterilization process preformed according to the manufacturer s instructions. After the sterilization cycle, the strips were transferred to culture medium and incubated at 56°C for 48 Hours. As control sample, a biologic indicator that had not been autoclaved was used for each group. Results: Being loaded in different autoclaves, All 48 turbines were sterilized properly and all the cultures were negative. The culture results of four control indicators which were not sterilized, were positive. Conclusion: There was no difference between performance of vacuum and non-vacuum autoclaves in dental turbine chamber sterilization. Both types performed sterilization properly

کلمات کلیدی:
Autoclave, dental turbine, sterilization, vacuum

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/942737/