A Three-dimensional Finite Element Analysis of Stress Distribution in Inclined Placed Implants

سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 174

فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JDMT-9-3_007

تاریخ نمایه سازی: 19 دی 1399

چکیده مقاله:

Introduction: Short implants are considered as a sole option in many patients due to anatomical limitations. It was aimed to assess the functional load stress at implants, surrounding bone and superstructures with different inclination angle. Methods: Seven finite element models with three implants (4 mm × 8 mm) and a separate model with longer implants (4 mm× 10 mm) with an angulation of 37° were designed. The implants were first placed vertically and then angled in distal direction preserving their parallelism increasing 6 ° at each step. Chromium-Cobalt was used to prepare superstructures. Oblique force of 100 N was applied on superstructures. Result: Inclined implant replacement did not significantly increase stress and compressive forces on bone, and the stress on implant surrounding bone decreased as inclination angle increased. On the other hand, in the model with linger implant more homogenous stress distribution was observed and implant’s von Mises values ​​decreased. Conclusion: Inclination of implants could have no detrimental effects on bone. Furthermore, inclination of implants provides the opportunity of placing longer implants and also more favorable stress distribution around the implants and in bone.

نویسندگان

Emel Yurekli

Research Assistant, Ministry of Health Mamak Oral and Dental Health Center, Ankara, Turkey

Serhat Emre Ozkir

Associate Professor, Osmangazi University, Faculty of Dentistry, Department of Prosthodontics, Eskişehir, Turkey

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Bellini CM, Romeo D, Galbusera F, Agliardi E, Pietrabissa R, ...
  • Aparicio C, Perales P, Rangert B. Tilted implants as an ...
  • Das Neves FD, Fones D, Bernardes SR, Do Prado CJ, ...
  • Renouard F, Nisand D. Impact of implant length and diameter ...
  • Galindu DF, Butura CC. Immediately loaded mandibular fixed implant prostheses ...
  • Del Fabbro M, Bellini CM, Romeo D, Francetti L. Tilted ...
  • Rangert B, Sullivon RM, Jemt T. Load factor control for ...
  • Tasa S, Strengoiu R, Kitamura E. Influence of implant design ...
  • Branemark PI, Grandahl K, Ohrnell LO. Zygomofixture in the management ...
  • Ozan O, Kurtulmus-Yilmaz Sevcan. Biomechanical Comparison of Different Implant Inclinations ...
  • Krekmonov L, Kahn M, Rangert B, Lindstorm H. Tilting of ...
  • De Vico G, Bonino M, Spinelli D, Schiavetti R, Sannino ...
  • Babbush CA, Kutsko GT, Brokloff J. The all-on-four immediate function ...
  • Wakabayashi N, Ona M, Suzuki T, Igarashi Y. Nonlinear finite ...
  • Sevimay M, Turhan F, Kilicarslan MA, Eskitascioglu G. Three-dimensional finite ...
  • Zampelis A, Rangert B, Heijl L. Tilting of splinted implants ...
  • Lan TH, Pan CY, Lee HE, Huang HL, Wang CH. ...
  • Malo P, Rangert B, Nobre M. “All on four” immediate-function ...
  • Malo P, Rangert B, Nobre M. “All on four” immediate-function ...
  • Malo P, De Araujo Nobre M, Petersson U, Wigren S. ...
  • Weinstein R, Agliardi E, Fabbro MD, Romeo D, Francetti L. ...
  • Mozzati M, Arata V, Gallesio G, Mussano F, Carossa S. ...
  • Capelli M, Zuffetti F, Del Fabbro M, Testori T. Immediate ...
  • Hinze M, Thalmair T, Bolz W, Wachtel H. Immediate loading ...
  • Malo P, De Araujo Nobre M. Implants (3.3 mm diameter) ...
  • Malo P, Nobre MDA, Lopes A. Immediate rehabilitation of completely ...
  • Crespi R, Vinci R, Cappare P, Romanos GE, Gherlone E. ...
  • Watanabe F, Hata Y, Komatsu S, Ramos TC, Fukuda H. ...
  • Canay S, Hersek N, Akpinar I, Asik Z. Comparison of ...
  • Bevilacqua M, Tealdo T, Pera F, Menini M, Mossolov A, ...
  • Bellini CM, Romeo D, Galbusera F, Taschieri S, Raimondi MT, ...
  • Gümrükçü Z, Korkmaz YT; Korkmaz FM. Biomechanical evaluation of implant-supported ...
  • Lee JH, Frias V, Lee KW, Wright RF. Effect of ...
  • Petrie CS, Williams JL. Comparative evaluation of implant designs: influence ...
  • Yokoyama S, Wakabayashi N, Shiota M, Ohyama T. The influence ...
  • Lin CL, Kuo YC, Lin TS. Effects of dental implant ...
  • Peixoto HE, Camati PR, Faot F, Sotto-Maior BS, Martinez EF, ...
  • نمایش کامل مراجع