Evaluation of organs at risk dose in the left breast IOERT procedures whit and without shielding disc using monte carlo simulation

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 38

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-15-0_435

تاریخ نمایه سازی: 29 آذر 1402

چکیده مقاله:

Introduction: One of the treatment choices in breast cancer is Intra operative electron beam radiation therapy (IOERT). Due to high dose delivery in this procedure, shielding disk is used to protect organs at risk (OARs). In this study, we evaluate the OARs dose in the breast IOERT using Monte Carlo simulation with and without shielding disk in RANDO phantom. Material and Methods: Simulation of dedicated IOERT linear accelerator (LIAC) head with ۵cm diameter applicator was performed using BEAMnrc Monte Carlo simulation cod. Three phase-space files for each nominal electron beam energies (۶,۸,۱۰,۱۲ MeV) produced in the end of the applicator, after ۲ cm tissue in the end of applicator. The last phase-space was created after disk. These phase- space were used in DOSXYZnrc for irradiation of RANDO phantom. Both lungs and heart were considered as OARs in the IOERT of the left breast irradiation. For each energy, the ۳ddose files, as an output of DOSXYZnrc and contoured organs in the RANDO phantom imported to CERR software. ۱۲Gy was considered as a normalized value in the target. Then dose-volume- histogram (DVH) data were extracted for analysis. Results: The mean and maximum dose for each OAR in all energies with and without disk and with consideration of ۲ cm tissue as a target were extracted from DVH data. For all nominal energies, the right lung dose was zero. The maximum and mean dose range in the left lung without disk were ۱۱.۵-۱۳.۹ and ۰.۱۵-۰.۵ Gy, respectively. These values for heart were ۰-۲.۹ and ۰-۰.۱۶Gy. The mean dose of heart and the left lung were un-remarkable with applying ۲cm tissue and disk. Conclusion: With the increase of the electron beam energy in the IOERT, an increase of OARs dose was seen with and without shielding disk application. On the other hand, application of shielding disk in breast IOERT reduces OARs dose significantly

نویسندگان

Ghazale Mansorian

Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran Department of Radiation Sciences, School of Para medicine, Iran University of Medical Sciences, Tehran, Iran

Ali Neshasteh-Riz

Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran

Mostafa Robatjazi

Department of Medical Physics and Radiological Sciences, Faculty of Medicine, Sabzevar University

Fereshteh Koosha

Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran Department of Radiation Sciences, School of Para medicine, Iran University of Medical Sciences, Tehran, Iran

Reza Paydar

Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran Department of Radiation Sciences, School of Para medicine, Iran University of Medical Sciences, Tehran, Iran