STI FFENER REQUIREMENTS IN STIFFENED STEEL PLATE SHEAR WALLS

سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 230

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

SEE07_206

تاریخ نمایه سازی: 29 آذر 1399

چکیده مقاله:

The 6-story Olive View Medical Center in California and the 35-story Kobe City Hall tower, both of which showed good performance w hile withstanding earthquakes, are two examples of structures that were constructed using stiffened steel plate shear walls as a lateral load resisting systemm. Stiffeners are used in such lateral load resisting systems t o improve the buckling stability of the shear panel. However, using plate girder equations often leads to unec onomical and, in some cases, incorrect design of stiffeners due to major differences between plate girders an d steel plate shear walls (SPSWs).In this paper, the effect of the rigidity and arrangement of stiffeners on the buckling behavior of plates is studied using th e finite element method (FEM). Subsequently figures cover ing curves for the design of stiffeners in various practical configurations are presented.

کلیدواژه ها:

نویسندگان

Ahmad RAHMZADEH

Earthquake Eng ineering Graduate Student, School of Civil Engineering, College o f Engineering, University of Tehran, Tehran, Iran

Mehdi GHASSEMIEH

Associate Professor, School of Civ il Engineering, College of Engineering, University of Tehran, Tehran, Iran