The Dosimetric Performance of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy in the Treatment of Locally Advanced Laryngeal Cancer
محل انتشار: مجله سرطان خاورمیانه، دوره: 15، شماره: 1
سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 46
فایل این مقاله در 15 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_MISJ-15-1_004
تاریخ نمایه سازی: 16 دی 1402
چکیده مقاله:
Background: This study aims to compare the performance of intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in treating laryngeal cancer.Method: In this retrospective dosimetric study, ۱۵ patients diagnosed with locally advanced laryngeal cancer (LALC) were selected. The dosimetric performance of the two techniques was analyzed using ۶ MV X-rays, based on dose-volume histograms for primary and boost planning target volumes (PTVp and PTVb, respectively), relevant organs at risk (OARs), mean Dose (Dmean), maximum Dose (Dmax), ۹۵% Dose (D۹۵), ۲% Dose (D۲%), ۵% Dose (D۵%), monitor units per segment (MU/segment), number of MU/cGy, treatment delivery time, along with conformity and homogeneity indices.Results: Both techniques were able to achieve favorable equivalent uniform doses and low doses to OARs. The average total number of monitor units for IMRT was significantly greater than that for VMAT (۱۷۲۴.۵ ± ۲۴۹.۵ and ۴۷۵.۳ ± ۴۷.۰, respectively for PTVp and ۶۰۱.۴ ± ۸۱.۷ and ۴۵۸.۰ ± ۶۲.۶, respectively for PTVb). The modulation factor (MU/cGy) of IMRT was significantly greater than that for VMAT for both the primary and the boost phases. The mean treatment delivery time for all cases of IMRT was significantly longer than that of VMAT.Conclusion: The primary distinction between IMRT and VMAT in the treatment of LALC is that VMAT requires significantly fewer monitor units (one-third) compared with IMRT. This reduction contributes to a decrease in treatment time, which in turn positively impacts patient comfort and the accuracy of treatment.
کلیدواژه ها:
نویسندگان
Firas Khater
Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
Ehab Attalla
National Cancer Institute, Cairo University, Giza, Egypt
Wael Elshemey
Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
Haitham Mohammed
Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :