Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation

سال انتشار: 1394
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 33

فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JBPE-5-2_007

تاریخ نمایه سازی: 30 دی 1402

چکیده مقاله:

Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for alternative materials to be used instead of lead apron because of some problems derived from lead-content of aprons. Because of its lead-content, these radiation protection garments are so heavy and uncomfortable for the staff to wear, particularly in long-time uses. In addition, lead is a toxic element and its disposal is associated with environmental and human-health hazards. Method: In this study, several new combinations of lead free materials ((W-Si), (W-Sn-Ba-EPVC), (W-Sn-Cd-EPVC)) have been investigated in the energy range of diagnostic radiology in two geometries: narrow and broad beam. Geometries of the radiation attenuation characteristics of these materials was assessed in ۴۰, ۶۰, ۹۰ and ۱۲۰ kVp and the results compared with those of some lead-containing materials ((Pb-Si), (Pb-EPVC)). Results: lead shields still provide better protection in low energies (below ۴۰ kVp). Combination of W-Sn-Cd-EPVC has shown the best radiation attenuation features in ۶۰ and ۹۰ kVp and the composition of (W-Sn-Ba-EPVC) represents the best attenuation in ۱۲۰ kVp, even better than previously mentioned lead- containing composites.Conclusion: Lead free shields are completely effective for protection against X-ray energies in the range of ۶۰ to ۱۲۰ kVp.

کلیدواژه ها:

Lead free sheilds ، MCNP۴C ، Diagnostic radiology energy range ، Radiation protection garments ، Narrow beam and broad beam geometry

نویسندگان

M Kazempoor

۱. MSc, Department of Radiobiology, School of paramedical sciences, Shiraz University of Medical Sciences, Shiraz, Iran; ۲. Student Research Committee, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran;

M Saeedimoghadam

Ionizing and Non-Ionizing Radiation protection research center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran

N Shokrpoor

English department, faculty of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran