THE EFFECT OF GAS INJECTION LOCATION ON MIXING PARAMETERS OF AN AIR-LIFT REACTOR
محل انتشار: دوازدهمین کنگره ملی مهندسی شیمی ایران
سال انتشار: 1387
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,471
فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
NICEC12_101
تاریخ نمایه سازی: 30 شهریور 1387
چکیده مقاله:
In this work, the effect of gas injection location on the operational hydrodynamic parameters such as liquid circulation velocity, circulation time and mixing time in two internal loop airlift reactor were investigated. The two reactors were structured in the way that gas was fed to inner tube in one of them, and to outer tube (annulus) in another. The cross sectional area of annulus to inner tube was 1.71. The tracer injection method and impulse response was used to determine the mixing parameters. The results showed when gas sparger was located in inner tube, liquid circulation time and mixing time were more than while gas sparger was located in annulus. The obtained results for liquid circulation velocity was vice-versa. This is due to more wall effects, more energy losses and pressure drop in the case of gas injection in inner tube.
کلیدواژه ها:
نویسندگان
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :