Behavior of steel shear walls subjected to fire

سال انتشار: 1396
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 379

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

این مقاله در بخشهای موضوعی زیر دسته بندی شده است:

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ISSEE04_244

تاریخ نمایه سازی: 8 تیر 1398

چکیده مقاله:

The steel shear walls are a new resistant system against lateral loads such as wind and earthquake loads. The steel shear wall has the lateral displacement smaller than the concentric bracing system. On the other hands, it reduces consumption of steel by up to 50% in comparison to the steel moment frame. Therefore, it is used extensively in high-rise steel buildings. Despite its great advantages, the steel has a low resistance to fire and the behavior of the steel shear wall against fire is very important. Therefore, the behavior of the steel shear wall subjected to fire is studied in this paper. The realistic fire event and ISO-834 standard fire curves are considered. According to the results, it has been observed that the amount of displacement and duration of resistance in the realistic fire is more than its amount in the ISO-834 standard fire, and the beams have more resistance under fire.

کلیدواژه ها:

نویسندگان

Amin Ghannadiasl

Assistant Professor, Mohaghegh Ardabili University, Ardabil, Iran

Arezoo Gharibi Asl

Master of Science, Mohaghegh Ardabili University, Ardabil, Iran